尊龙凯时人生就是搏

±ê×¼¹âÄ£¿é

±ê׼ЭÒé¹âÄ£¿é

¼æÈÝЭÒé¹âÄ£¿é

ÆäËüÖÖÀà¹âÆ÷¼þ

ÊÖÒÕÖ§³Ö

1¡ÁN ¹â¿ª¹Ø

1¡ÁN ¹â¿ª¹Ø

0.0/5 rating (0 votes)

Description

1×N ¹â¿ª¹Ø

²úÆ·ÏÈÈÝ

1×N Optical switch is a kind of functional component, with the ability of switching optical route. In optical fiber transmission system, it is used for multi-channel fiber monitoring, multi light source/ detector selection, and optical fiber path protection etc. Besides, it is also used in optical fiber test system for optical fiber and its component test, outdoor cable test and multi-spot optical sensors monitoring system.

Specifications

Parameters

Unit

FSW-1×N

Insertion Loss

dB

1<N8

<N16

17 <N64

65 <N128

Typ: 0.6 Max: 0.8

Typ: 0.8 Max: 1.0

Typ: 0.8 Max: 1.2

Wavelength Range

nm

850±40 /13040

1260~ 1650

Test Wavelength

nm

850 / 1300

1310/1550

Return Loss

dB

MM30   SM50

Crosstalk

dB

MM 55   SM 70

PDL

dB

0.05

0.1

WDL

dB

0.25

TDL

dB

0.25

Repeatability

dB

±0.02

±0.05

Durability

Cycles

 10 Million

Switching Time

ms

 10 (Sequence switch time of adjacent channel)

Optical Power

mW

≤500

OperatingTemperature

¡æ

-20~+70

Storage Temperature

¡æ

-40~+85

Relative Humidity

%

~95

Dimension

mm

135×64×32 (N≤16)

150×80×32 (9≤N≤16)

150×80×70 (17≤N≤64)

150×150×70 (65≤N≤128)

Pin Configurations

∨DB-9 male connector 

Pin No.

Signal Name

I / O

    Description

1

D0

Input

TTL, Channel selection bit 0

2

D1

Input

TTL, Channel selection bit 1

3

D2

Input

TTL, Channel selection bit 2

4

D3

Input

TTL, Channel selection bit 3

5

/RESET

Input

TTL, Low level reset to channel 0. High level means channel selection bits are effective.

6

/READY

Output

TTL, Ready (High=Not ready, Low=Ready)

7

ERROR

Output

TTL, Error (High=Error, Low=No error)

8

GND

Input

Ground

9

+5VDC

Input

5.0±5% VDC Power Supply (max 650mA)

DB-15 male connector  

Pin No.

Signal Name

I / O

    Description

2

D0

Input

TTL, Channel selection bit 0

3

D1

Input

TTL, Channel selection bit 1

4

D2

Input

TTL, Channel selection bit 2

5

D3

Input

TTL, Channel selection bit 3

6

D4

Input

TTL, Channel selection bit 4

11

/RESET

Input

TTL, Low level reset to channel 0. High level means channel selection bits are effective.

7

/READY

Output

TTL, Ready (High=Not ready, Low=Ready)

8

ERROR

Output

TTL, Error (High=Error, Low=No error)

1, 9

GND

Input

Ground

15

+5VDC

Input

5.0±5% VDC Digital power supply (max 50mA)

12

VM

Input

5.0±5% VDC Drive power supply (max 600mA)

10, 13, 14

NA

∨DB-25 male connector 

Pin No.

Signal Name

I / O

    Description

15

D0

Input

TTL, Channel selection bit 0

16

D1

Input

TTL, Channel selection bit 1

17

D2

Input

TTL, Channel selection bit 2

18

D3

Input

TTL, Channel selection bit 3

19

D4

Input

TTL, Channel selection bit 4

20

D5

Input

TTL, Channel selection bit 5

21

D6

Input

TTL, Channel selection bit 6

22

/RESET

Input

TTL, Low level reset to channel 0. High level means channel selection bits are effective.

2

/READY

Output

TTL, Ready (High=Not ready, Low=Ready)

3

ERROR

Output

TTL, Error (High=Error, Low=No error)

1, 10, 14, 23

GND

Input

Ground

12, 25

+5VDC

Input

5.0±5% VDC Digital power supply (max 50mA)

13

VM

Input

5.0±5% VDC Drive power supply

N≤64

Current supply ≤600mA

11, 24

N≤128

Current supply ≤800mA

4, 5, 6, 7, 8, 9

NA

Channel Selection Table

Max Channel

Input

Active Channel

/RESET

D6

D5

D4

D3

D2

D1

D0

N=16

0

x

x

x

x

x

x

x

     0 reset

1

x

x

x

0

0

0

0

COM → 1

x

x

x

0

0

0

1

COM → 2

x

x

x

0

0

1

0

COM → 3

x

x

x

x

x

x

1

1

1

1

COM → 16

N=128

0

x

x

x

x

x

x

x

     0 reset

1

0

0

0

0

0

0

0

COM → 1

0

0

0

0

0

0

1

COM → 2

0

0

0

0

0

1

0

COM → 3

1

1

1

1

1

1

1

COM → 128

Optical Route

尊龙凯时·(中国游)官方网站

Timing Diagram

尊龙凯时·(中国游)官方网站

Dimension

>02: 135×64×32-DB9  (N16, DB-9 male)

尊龙凯时·(中国游)官方网站

>23£º  150×80×32 - DB15  (N16, DB-15 male)

尊龙凯时·(中国游)官方网站

 

>24:  150×80×70 -DB25  (17N64, DB-25 male)

尊龙凯时·(中国游)官方网站

>26£º 150×150×70 -DB25  (65N128, DB-25 male)

尊龙凯时·(中国游)官方网站

 

Ordering Information:  FSW-1×N-A-B-C-D-E-F

N

A

B

C

D

E

F

Channel

Fiber Type

Test Wavelength

Tube Type

Fiber Length

(Include connector)

Connector

Dimension

1 ~ 128

SM:SM, 9/125

M5:MM, 50/125

M6:MM,62.5/125

X: Others

850850nm

13101310nm

15501550nm

1310/1550:

1310/1550nm

X:Others

90:900um

20:2.0mm

X: Others

05:0.5m±5cm

10:1.0m±5cm

X: Others

OO:None

FP:FC/PC

FA: FC/APC

SP: SC/PC

SA: SC/APC

LP: LC/PC

LA: LC/APC

X: Others

02: 135×64×32-DB9

23: 150×80×32-DB15

24: 150×80×70-DB25

26: 150×150×70-DB25

X: Others

 

 

 

 

 

 

Important Notice

Performance figures, data and any illustrative material provided in this data sheet are typical and must be specifically confirmed in writing by F-tone Networks before they become applicable to any particular order or contract. In accordance with the F-tone Networks policy of continuous improvement specifications may change without notice.
The publication of information in this data sheet does not imply freedom from patent or other protective rights of F-tone Networks or others. Further details are available from any F-tone Networks sales representative.

Search

sitemap¡¢ÍøÕ¾µØͼ